WaveMon RF-60

Personal RF Monitor: E/H Field Up to 60 GHz

ELECTRIC AND MAGNETIC FIELD DETECTION

Isotropic sensors with RMS response

 

WEIGHTED RESPONSE TO INTERNATIONAL STANDARDS

ICNIRP, European Directive 2013/35/EU, FCC, Safety Code 6 (2015) and NATO

 

INSTANT AND AVERAGE VALUES

Alarms on instant and average values. Configurable

 

EXPOSIMETER WITH DATALOGGER

Data collecting and Reporting

 

GPS AND ALTIMETER

Geolocation of measurements

 

HIGH INTENSITY AUDIBLE, VISIBLE AND VIBRATORY ALARM

With user definable trigger threshold

 

USB COMMUNICATION PORT

Data downloading, set-up and battery charging

MORE VIDEOS

WEIGHTED RESPONSE

The WaveMon gives a specific weighted response for each standard. It is not just single model that attempts to follow all standards at once. Such an approach will always result in poorer accuracy. This is a weighted response, designed to follow the limits of the applicable standard, for greater accuracy.

 

The following monitors are now available:

 

  • WaveMon RF-60 ICN → ICNIRP version
  • WaveMon RF-60 EUD → European Directive 2013/35/EU version
  • WaveMon RF-60 FCC → FCC version
  • WaveMon RF-60 SC6 → Safety Code 6 (2015) version
  • WaveMon RF-60 NATO → NATO version

 

If you need a personal radio frequency monitor that specifically follows some other standard, please let us know.

DATALOGGER

The WaveMon is a radio frequency exposimeter that have a datalogger for continuous data recording.

Communication with the device is through a USB port that allows you to parametrise the device and download the recorded data. This makes it easy to create reports and allows you to keep a record of your exposure data for your safety.

BATTERIES

The device is small and lightweight and works with AA batteries that can be recharged via the USB port. It can also use standard AA batteries, so that they can always be easily replaced.

 

Easy, isn’t it? Because we want you always to be protected.

PRACTICALITY

We have created an accessory that allows you to attach the personal RF monitor to your harness, arm or belt and so take it in hand to hold it near a radiation source and then put it back in place easily.

 

You can also secure it with a small carabiner so that it won’t be dropped.

GPS AND ALTIMETER

The WaveMon is the only RF personal monitor equipped with a GPS and Altimeter for geolocation of measurements.

 

As an example, in a telecommunication tower, the GPS will provide the geographical position of the tower and the Altimeter the relative height from the ground. Thus, the radio frequency monitor will record ‘Exposure Level’ together with ‘Date’, ‘Time’, ‘Geographical Position’ and ‘Height’ on the Tower, allowing you to perfectly locate the hotspots.

ALARMS ON INSTANT AND AVERAGE VALUES

The WaveMon is the only personal RF monitor that can give alarms for average value and instantaneous value at the same time.

 

Remember that internationally established exposure limits are specified as values averaged over a given time (e.g. 6 or 30 minutes). Some important examples include the limits established under ICNIRP, FCC, Safety Code 6, European Directive 2013/35/EU, etc.

USER-CONFIGURABLE ALARMS

Over-exposure alarms can be configured from a PC with all their parameters. Two different alarms can be programmed and personalised separately. The following basic parameters can be personalised:

 

  • Value type (generated by instantaneous or average value)
  • Alarm level (% of limit)
  • Type of alarm (sound, vibration or both)

LOW FREQUENCY IMMUNITY

Experience shows that personal RF monitors with poor immunity to low frequencies give false alarms near high-voltage lines or other types of powerful electric equipment.

 

The WaveMon is the personal monitor with the best immunity and it can work in electric field intensity conditions of up to 30 kV/m at 50/60 Hz without giving false readings of non-existent RF levels. That is better, for example, than the occupational exposure limit under ICNIRP: 20 kV/m.

RF ABSORTION

When the personal monitor is worn on the body, which is how it is most often used, reflections of electromagnetic fields from the body itself can affect the measurement and compromise its accuracy.

 

The holder for the WaveMon includes an RF absorbent material to reduce that effect. When the device is in the holder, next to the body, the absorbent material is placed strategically between the sensor and the body, but when it is used away from the body, outside the holder, that material is not present and the WaveMon gives an undisturbed isotropic behaviour.

LOW FREQUENCY IMMUNITY

Experience shows that personal RF monitors with poor immunity to low frequencies give false alarms near high-voltage lines or other types of powerful electric equipment.

 

The WaveMon is the personal monitor with the best immunity and it can work in electric field intensity conditions of up to 30 kV/m at 50/60 Hz without giving false readings of non-existent RF levels. That is better, for example, than the occupational exposure limit under ICNIRP: 20 kV/m.

EXPOSIMETER MAIN FEATURES

  • According to the international standards on EMF safety.

  • E-field measurements up to 8 GHz and H-field measurements up to 1 GHz.

  • Isotropic sensors.

  • RMS detection.

  • Weighted response for direct comparison to a specific limit: ICNIRP, European Directive 2012/35/EU, FCC or Safety Code 6 (2015).

  • High intensity audible, visible and vibratory alarms.
  •  
  • Optional GPS and Altimeter.

  • User-defined alarm threshold.

  • Datalogger for reporting and historical registry of data.

  • PC USB connection for data downloading and configuration.

  • Small and light.

  • Powered by two standard AA batteries, disposable or rechargeable through its USB port.

  • More than 200 hours autonomy.
  •  

ACCESSORIES

GPS

Wavestick

Safety Cable

WaveMon Lanyard

APPLICATIONS

철도

연구소

의료

방위

통신

전력

RFID/EAS

산업

logo

TEL : 02-384-8740
FAX : 02-384-8741
info@sevitkorea.com

LOCATION

이용약관   |   개인 정보 보호 정책

(10090) 경기도 김포시 태장로 755, GTower 지식산업센터 503호 l 사업자등록번호 110-81-61448 ㅣ 대표이사 : 최형준
통신판매업신고 : 2017-경기김포-0888 ㅣ Contact for more information : info@sevitkorea.com

top